IDS-1 Pile Testing Device

This instrument " IDS-1" can determine the length of reinforced concrete and metal piles up to sixty meters in length. Engineers can also use "IDS -1" for surveying a structures' foundation and examining concrete hydraulic structures, as well as inspecting tunnels, sewers and underground storage tanks.

The High frequency two‐channel seismic station "IDS-1" is designed for the inspection of metal and reinforced concrete piles to 60 m in length, foundation walls, foundations of road and airport runways, in‐ground walls, bridge piles, and other concrete and stone‐made utilities.

 

FEATURES

Measuring acoustic wave velocity

Working with different modes of vibration

Can be used in a downhole version

Easy and user-friendly interface

Automatic data processing

Several languages option (Russian, English)

Specially designed for a variety of weather conditions

Free training

After-sales service

Consulting webinars.

 

APPLICATIONS

Determining the length, integrity, average strength, and defects of piles

Surveying structures foundation

Examining concrete hydraulic structures

Inspecting tunnels, sewers, underground storage tanks

Measuring thickness of foundation slab and detecting cavities under them

Examining condition and strength of concrete structure.

 

VIDEO

 

Software IMPACT-METHOD

The software is used for automotive basic plates thickness, possible defects detection, survey the plate and soil engagement condition.

 

Software Pilemeter

Specialized PILEMETER software provides automated detection of the length of a pile or rate of the acoustic wave in the pile, and, more importantly, allows one to collect this necessary data easily and clearly. This Specialized software also helps to determine the thickness and defects of piles using the Impact Echo Principle.

It also..

Once the longitudinal wave velocity in the pile is defined, this software determines the length, integrity and localizing defects of piles.

 

The IDS-1 set includes:

Electronic module

Seismic pick-ups

Charging unit

Set of cables

Set of documentation

Transportation bag

Pile length measuring method

The method is based on measuring the response time for the signal reflected from the other end of pile or from obstacles inside the pile that emerge due to its inhomogeneity. The lenght is calculated based on the known speed of primary wave for various types of piles and measured response time. The source of primary waves is a special hammer; the seismic pick up serves as a pick up of elastic vibration.

 

SEISMOGRAPHS BROCHURE

 Pile Length Range, m  up to 60
 Number of Channels  2 + timing channel
 Channel Bandpass, KHz  8; 4; 2; 1; 0; 0.5
 Discretization Interval, KHz  96; 32; 16; 8; 4; 2
 Scale Numbering per Recording per Channel  2048
 Instant Dynamic Range, dB  95
 System Dynamic Range, dB  140
 Noise Voltage, microV  0.2
 Distortion, %  no more than 0.1
 Storage Capacity, MB  512
 Weight with Built-in Battery, kg  2.8
 Running time, hr  10
 Temperature range  -20ºC ... +50ºC
 Display resolution, points  320 x 240
 Screen size, mm  120 x 92

IDS-1 Software, 2,45 Mb

 

SOFTWARE IMPACT-METHOD

The software is used for automotive basic plates thickness, possible defects detection, survey the plate and soil engagement condition.

Software Pilemeter

Specialized PILEMETER software provides automated detection of the length of a pile or rate of the acoustic wave in the pile, and, more importantly,allows one to collect this necessary data easily and clearly. This Specialized software also helps to determine the thickness and defects of piles using the Impact Echo Principle. It also.. Once the longitudinal wave velocity in the pile is defined, this software determines the length, integrity and localizing defects of piles.

We will contact you within 24 hours Email